Home › Storage › Dell

Dell PowerVault MD3400

End of saleStorage2U rack
Dell PowerVault MD34002U rack12 × LFF 3.5" baysmax 16 GB

The Dell PowerVault MD3400 is an upgraded 2U hardware RAID storage array delivering 12Gb/s direct-attached SAS connectivity for high-speed shared clustering. Featuring dual active-active controllers with up to 16GB of total cache memory, the MD3400 houses twelve 3.5-inch drives and supports expansion up to 192 drives via MD1400 expansion enclosures. Delivering twice the throughput of legacy 6Gb SAS systems, it connects directly to host servers equipped with 12Gb SAS HBAs (such as the Dell 12Gbps HBA) using mini-SAS HD cabling. Refurbished buyers should test controller battery packs and confirm SFF-8644 cables.

Also written as: PowerVault MD3400, Dell MD3400, MD3400 12Gb SAS Array

Buy Dell PowerVault MD3400Sell yours

Specifications

BrandDell
FamilyPowerVault
Form factor2U rack
ReleasedSep 2014
End of saleFeb 2019
End of supportMar 2024
Cpu platformDual active-active hardware RAID controllers, 4GB or 8GB battery-backed cache per controller
Memory max (GB)16
Drive bays12x 3.5-inch SAS/NL-SAS/SSD drives in base array; expands up to 192 drives across MD1400 DAEs
Raw capacityUp to 192TB raw in base enclosure (up to 1.5 PB fully expanded)
Network onboard4x 12Gb/s mini-SAS HD (SFF-8644) host ports per controller; 1x 1GbE management port
Power supplyDual redundant hot-plug 600W power supplies

Generations

Compatible parts

Transceivers

Works together

How the Dell PowerVault MD3400 connects to servers, storage and the network: 1 way, with the parts and products on each path.

Direct-attached SAS

Direct-attached SAS

12Gb SAS uses Mini-SAS HD (SFF-8644) connectors; older 6Gb gear uses Mini-SAS (SFF-8088). Adapter cables exist, but the link runs at the slower speed.

Servers

Adapters for the server

Direct-attached SAS: how it fits together

Plan and size it

Equivalent models from other brands

Buying a used MD3400: what to check

Verify dual 12Gb SAS controllers with SFF-8644 ports, test cache backup batteries, check all 12 drive trays, and verify MDSM management network access.

FAQ

What interface does the MD3400 use for host connectivity?

High-speed 12Gb/s mini-SAS HD (SFF-8644) ports, offering double the bandwidth of previous 6Gb systems.

How many servers can share the MD3400 directly?

Up to four servers in dual-path redundant configurations without needing external SAS switches.

Buying or selling MD3400?

New, refurbished or used. Tell us the quantity and condition and we connect you with a vetted reseller in your region, usually within one working day.

Sources