Home › Network › Dell

Dell Connectrix ED-DCX6-4B

CurrentNetwork9U director chassis
Dell Connectrix ED-DCX6-4B9U director chassis

The Dell Connectrix ED-DCX6-4B is a 9U 4-slot modular enterprise director based on the Brocade X6-4 platform. Providing five-nines availability and scaling up to 256 32Gb/s Fibre Channel ports, the ED-DCX6-4B delivers non-blocking switching matrix throughput, fully redundant control processors, and integrated IOPS telemetry for enterprise core SAN backbones.

Also written as: Connectrix ED-DCX6-4B, Dell Connectrix ED-DCX6-4B, DCX6-4B 4-Slot Director

Buy Dell Connectrix ED-DCX6-4BSell yours

Specifications

BrandDell
FamilyConnectrix
Form factor9U director chassis
ReleasedSep 2016
Slot count4 horizontal port blade slots + 2 Control Processor (CP) slots + 2 Core Routing (CR) slots in 9U
Port countUp to 256x 32Gb/s Fibre Channel ports or 128x 128Gb/s QSFP links
Switching bandwidth10.24 Tbps aggregate chassis bandwidth
Operating systemBrocade Fabric OS (FOS) enterprise director edition
Power supplyQuad redundant hot-plug power supplies with hot-swappable blower assemblies

Generations

Compatible parts

HBAs

Transceivers

Rail kits

Works together

How the Dell Connectrix ED-DCX6-4B connects to servers, storage and the network: 1 way, with the parts and products on each path.

Fibre Channel SAN

Fibre Channel SAN

Match the speed: 16Gb and 32Gb FC HBAs, switches and array ports work together, and each generation also runs one or two speeds below its own (a 32Gb port runs at 16Gb and 8Gb).

Servers

Adapters for the server

Storage

Optics

Fibre Channel SAN: how it fits together

Plan and size it

Check compatibility with Dell

Before you buy, confirm the exact configuration against the vendor's own lists: firmware levels, operating systems, adapters and optics that Dell has tested with the Dell Connectrix ED-DCX6-4B.

Equivalent models from other brands

Buying a used Connectrix ED-DCX6-4B: what to check

Examine Core Routing (CR) and Control Processor (CP) module pairs, confirm active port blade types (32Gb 48-port or 64-port blades), test all four power supplies, and verify enterprise licenses.

FAQ

Can the ED-DCX6-4B support mainframe FICON?

Yes, with the appropriate FICON Control Unit Port (CUP) licenses, it supports mixed open systems and mainframe FICON on the same chassis.

What is the failover mechanism for director controllers?

Active/standby redundant Control Processors (CPs) provide hitless stateful failover with zero dropped frames.