Home › Servers › Dell

Dell PowerEdge XR2

Servers1U rack (short-depth, rugged)
Dell PowerEdge XR21U rack (short-depth, ru8 × SFF 2.5" bays

The Dell PowerEdge XR2 is a rugged 1U, dual-socket short-depth server for edge, military and field use, with a chassis depth of 547 mm. It takes up to two Intel Xeon Scalable processors, 16 DDR4 slots and eight 2.5-inch drive bays, and it can hold one low-profile 75 W GPU. Dell lists continuous operation from 5 C to 45 C and excursions to 55 C, with shock, vibration and altitude ratings taken from Mil-Std 810G. A common access card reader on the front panel supports drive encryption. Buyers are usually defence, telecom and mobile-site operators.

Also written as: PowerEdge XR2, Dell EMC PowerEdge XR2, XR2 Rugged Server, Dell XR2

Buy Dell PowerEdge XR2Sell yours

Specifications

BrandDell
FamilyPowerEdge XR
Form factor1U rack (short-depth, rugged)
ReleasedOct 2017
Cpu sockets2
Cpu platformUp to two Intel Xeon Processor Scalable Family processors
Memory slots16
Memory typeDDR4 RDIMM / LRDIMM, 2666 / 2400 / 2133 / 1866 MT/s
Memory max (GB)2,048
Drive baysUp to 8x 2.5-inch hot-swap SAS or SATA SSD (with drive adapter); up to 4x 2.5-inch hot-swap NVMe
Pcie slotsRiser based: LOM riser (x8), right riser slot (x16, low profile or full height half length), left riser slot (x16, low profile half length), plus an internal riser
Gpu supportOne low-profile 75 W single-wide GPU, riser 2 only, with performance fans
Network onboard2x 1GbE NIC ports on the rear panel; iDRAC Direct micro-USB port
Power supplyTwo redundant PSUs: 550 W AC (Platinum) or 600 W DC (-48 V)

Compatible parts

Memory

SSDs

Boot devices

HBAs

Power supplies

TPM modules

Network adapters

Drive caddies

RAID controllers

Works together

How the Dell PowerEdge XR2 connects to servers, storage and the network: 4 ways, with the parts and products on each path.

Fibre Channel SANiSCSI and NVMe/TCP over EthernetDirect-attached SASFile storage (NFS and SMB)

Fibre Channel SAN

Match the speed: 16Gb and 32Gb FC HBAs, switches and array ports work together, and each generation also runs one or two speeds below its own (a 32Gb port runs at 16Gb and 8Gb).

Adapters for the server

Switches

Storage

Optics

Fibre Channel SAN: how it fits together

iSCSI and NVMe/TCP over Ethernet

Keep the speed the same at all three points: a 25GbE server, a 25GbE switch port and a 25GbE array port. Mixed speeds work but the slowest link sets the pace.

Adapters for the server

Switches

iSCSI and NVMe/TCP over Ethernet: how it fits together

Direct-attached SAS

12Gb SAS uses Mini-SAS HD (SFF-8644) connectors; older 6Gb gear uses Mini-SAS (SFF-8088). Adapter cables exist, but the link runs at the slower speed.

Adapters for the server (check the fit list)

Storage

Direct-attached SAS: how it fits together

File storage (NFS and SMB)

Front-end ports face the clients; back-end ports (on scale-out systems) connect the nodes to each other and need their own switch pair.

Adapters for the server

Switches

Storage

File storage (NFS and SMB): how it fits together

Plan and size it

Check compatibility with Dell

Before you buy, confirm the exact configuration against the vendor's own lists: firmware levels, operating systems, adapters and optics that Dell has tested with the Dell PowerEdge XR2.

Equivalent models from other brands

Buying a used XR2: what to check

Check which PSU type is fitted, because AC and -48 V DC versions are not interchangeable, and confirm the fan type if a GPU is present. Ask whether the front common access card reader and eSATA port are populated, and run diagnostics on all 16 DIMM slots. Check iDRAC licence level and that rails and the front bezel are included.

FAQ

How deep is the PowerEdge XR2?

Dell's technical specifications give a chassis depth of about 547 mm (21.35 inches) at the longest measure, with a width of 434 mm and a height of 42.8 mm. It is a 1U short-depth design.

What temperature range does the PowerEdge XR2 support?

Continuous operation is 5 C to 45 C, and Dell lists excursions to 55 C. An expanded range of -5 C to 55 C applies for up to 1 percent of annual operating hours, with redundant power supplies required.

Can the PowerEdge XR2 take a GPU?

Yes, one low-profile 75 W single-wide GPU is supported, in riser 2 only and with performance fans. Dell also notes GPU continuous operation is supported up to 30 C, or 45 C with the optional fan booster kit.

Buying or selling XR2?

New, refurbished or used. Tell us the quantity and condition and we connect you with a vetted reseller in your region, usually within one working day.